JXFSH Stainless Steel Outdoor Distribution Box
The JXFSH stainless steel outdoor distribution box is manufactured by LYE Technology in 201 or 304 stainless steel, in eight sizes from 300 x 250 x 160 mm to 1000 x 800 x 200 mm. Its wide, shallow proportions suit walls and posts, and built-in sealing strips let it be mounted on an exterior face without a canopy.
- Material: 201 or 304 grade stainless steel
- Sizes: Eight models from JXFSH-302516 to JXFSH-1008020
- Size range: 300 x 250 x 160 mm to 1000 x 800 x 200 mm
- Depths: 160 mm, 180 mm, 200 mm and 250 mm
- Sealing: Built-in sealing strips against water, rain and dust
Stainless Steel Outdoor Distribution Box: Key Features & Typical Use
Wide and Shallow for Wall Mounting
The JXFSH proportions are wider than they are tall, from 300 x 250 mm up to 1000 x 800 mm with a 160 to 200 mm depth. That shape suits a wall or a post where the available length is greater than the headroom, and it keeps the enclosure's projection off the wall small enough to avoid being caught by passing equipment.Sealed Against Exterior Conditions
Built-in sealing strips provide resistance to water, rain and dust, which is the difference between an enclosure that can be mounted on an exterior wall and one that needs a canopy over it. The 201 or 304 stainless steel body also means the shell does not depend on a coating to survive humid or coastal air.Eight Sizes for Exterior Circuit Groups
Eight models run from 300 x 250 x 160 mm to 1000 x 800 x 200 mm, covering small exterior lighting and power points through to a grouped outdoor distribution board for a site or a building perimeter. Because the steps are regular, an installation can be standardised on the same box across a large site.Prepared Off the Wall
Electrical equipment mounts on a detachable base plate, so the assembly is prepared and wired on a bench and then fixed into the enclosure. On exterior work, where weather and access limit how long a technician can stay in position, that reduces both the installation time and the risk of a partially completed connection being left exposed.Stainless Steel Outdoor Distribution Box Specifications & Technical Data
| Parameter | Details |
|---|---|
| Product | JXFSH stainless steel outdoor distribution box |
| Material | 201 or 304 grade stainless steel |
| JXFSH-302516 | 300 x 250 x 160 mm (W x H x D) |
| JXFSH-403018 | 400 x 300 x 180 mm (W x H x D) |
| JXFSH-504018 | 500 x 400 x 180 mm (W x H x D) |
| JXFSH-605018 | 600 x 500 x 180 mm (W x H x D) |
| JXFSH-705020 | 700 x 500 x 200 mm (W x H x D) |
| JXFSH-806020 | 800 x 600 x 200 mm (W x H x D) |
| JXFSH-806025 | 800 x 600 x 250 mm (W x H x D) |
| JXFSH-1008020 | 1000 x 800 x 200 mm (W x H x D) |
| Sealing | Built-in sealing strips against water, rain and dust |
| Internal mounting | Detachable mounting base plate |
| Installation environment | Outdoor and semi-exposed positions |
| Typical contents | Breakers, meters and control devices |
| Customisation | Hole drilling, custom printing, specified component brands |
JXFSH — Stainless Steel Outdoor Distribution Box
An outdoor distribution box has one job above all others: keep the connection dry. The JXFSH is fabricated from 201 or 304 stainless steel with built-in sealing strips for water, rain and dust resistance, so it can be mounted on an exterior wall or post without a canopy and still protect breakers, meters and control devices inside.It is also called a stainless steel outdoor consumer unit, a weatherproof breaker box or an exterior distribution board, and it is compared with plastic outdoor boxes and with larger outdoor cabinets. Because the box is often mounted where nobody visits it, the deciding factors for any supplier are the sealing system, the stainless grade and whether the base plate is prepared for your devices before dispatch.Eight sizes run from 300 x 250 x 160 mm to 1000 x 800 x 200 mm, and the proportions are deliberately wide and shallow. That suits walls and posts where length is easier to find than headroom, and it keeps the projection away from the wall small enough to avoid being caught as equipment or vehicles pass by.Internally, equipment mounts on a detachable base plate so the assembly is wired on a bench before installation. The box accepts knockouts, custom printing and complete-set assembly with the component brands your project specifies, and because the range steps are regular, a large site can standardise on one enclosure size across many positions.
Factory-Direct Stainless Steel Outdoor Distribution Box Manufacturer & OEM / ODM
We Manufacture, You Brand
LYE Technology (Zhejiang) Co., Ltd. is a national high-tech enterprise and manufacturer in Wenzhou, China: sheet-metal fabrication, welding, powder coating, busbar machining and final assembly run on our own factory lines, and every unit is function-tested before it leaves the works. A JXFSH Stainless Steel Outdoor Distribution Box that reaches your site carries the routine test behind it, not just the rating on the nameplate.We are one of the Top 10 Brands of China's small power distribution boxes and a drafter of national standards in this category, and we hold ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification. Because we are the manufacturer rather than a trading company, our sales engineers quote from your drawing in factory-direct terms, and OEM or ODM work is produced on the same lines as our standard products.For the JXFSH we fabricate the stainless enclosure and fit the sealing system in our own works, so a specific knockout or gland plate arrangement is settled at drawing stage.- OEM branding — custom colours, laser marking and your own project or retail packaging, applied at the factory.
- ODM options — ratings, configurations and internal layouts built around your drawings or single-line diagram.
- Certification — ISO9001, ISO14001, ISO45001, CCC, CE and TUV, with test documents supplied per project.
- MOQ — flexible quantities for a project or a trial order, with mixed types welcome in one shipment.

JXFSH-1008020 outdoor distribution box mounted on a wall

Sealing strip and base plate inside the stainless enclosure
Stainless Steel Outdoor Distribution Box Buying Guide from the Manufacturer
Outdoor boxes are ordered from the circuit list and the mounting position. These are the points we confirm before production.
- Confirm the number of circuits and the devices to be fitted so the correct size is selected.
- Confirm the mounting arrangement and the maximum projection acceptable off the wall.
- Confirm the environment, including coastal or chemical exposure, to select the steel grade.
- Confirm the cable entry direction and the number and size of knockouts required.
- Send the circuit schedule, mounting detail and site photographs.
- Approve the drawing, then production, inspection and dispatch.

Manufacturer & Sales Support for Wholesale Buyers

OEM / ODM
Learn more →Factory colours · Logo marking · Custom layout

Wholesale
Learn more →Factory pricing · Flexible MOQ · Global shipping

Distributor Support
Learn more →Account manager · Drawing support · Priority lead times
Need an Outdoor Distribution Box for a Site?
OEM/ODM, wholesale pricing and distributor support straight from the manufacturer — one enquiry gets you a factory-direct quotation for the JXFSH Stainless Steel Outdoor Distribution Box, sized to your circuit schedule, mounting arrangement and the maximum projection acceptable off the wall, with type-test documentation under IEC 60529 for enclosure protection. Our sales team replies with a specification and an indicative price, so send your drawings and quantity.Contact Our Sales TeamStainless Steel Outdoor Distribution Box — Frequently Asked Questions
What is a stainless steel outdoor distribution box?
It is an exterior distribution enclosure for circuits that have to be protected outside a building, housing breakers, meters and control devices. The JXFSH is fabricated from 201 or 304 grade stainless steel in eight sizes from 300 x 250 x 160 mm to 1000 x 800 x 200 mm, with built-in sealing strips for water, rain and dust resistance and a detachable mounting base plate.What is an outdoor distribution box used for?
It is used for exterior lighting and power circuits, gate and boundary supplies, pump and plant control points, car park and yard circuits, and any outdoor position where a breaker or meter has to be accessible. It is mounted on walls, posts and structural steel, so its shape is usually chosen to suit the surface rather than the room.What is the difference between IP65 and IP66 outdoor boxes?
Both protect against dust ingress, and both resist water projected from a nozzle; the difference is the severity of the water test, with IP66 covering more powerful jets. IP65 is sufficient for rain, splash and normal wash-down of an outdoor box, while IP66 is chosen where the enclosure will be hosed down directly or jet-washed, such as in food processing or agricultural buildings.Who manufactures outdoor distribution boxes?
This category is produced by many factories, and the visible differences are usually the stainless grade, the sealing design and whether components are prepared before dispatch. Ask which grade is supplied, how the cable entry is sealed so the enclosure rating is not lost at the gland, and whether the base plate can be drilled to your device list. LYE manufactures the JXFSH in Wenzhou on our own lines and holds ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification.How much does an outdoor distribution box cost?
Indicative factory-direct pricing is roughly US$50 to US$600 per box, depending on the size, the steel grade, the number of devices fitted and the quantity ordered. Because these boxes are bought in quantity across a site, the delivery schedule and batch consistency usually matter as much as the unit price, and mixed sizes can be supplied in one shipment.
Download PDF
Electrical Cabinet Product Catalog
Mini Distribution Box Product Catalog
Distribution Box Product Manual
Fiber Optic Box Product Manual
Fan Module Manual
Use a distribution box for final circuits and compact branch protection; use a cabinet when the project needs larger incoming capacity, more feeder groups, metering, busbars or greater internal separation. The final choice should be checked against the single-line diagram, device list, available installation space and local project rules.
Provide the device schedule, circuit quantity, component dimensions, cable-entry direction, mounting method and required spare capacity. LYE also reviews door clearance, bending radius, heat-producing devices and the usable depth behind the mounting plate before confirming an enclosure size.
Start with the actual exposure to dust, rain, cleaning water and accidental contact rather than choosing the highest number by default. Cable entries, ventilation, door seals and installation workmanship affect the finished assembly, so the target rating and verification basis must be confirmed for the specific product and project.
Coated or galvanized steel is commonly considered for general indoor service, stainless steel for humid or corrosive locations, and engineering plastic for lightweight non-metallic applications. Material grade, thickness, UV exposure, chemical contact and earthing requirements must be confirmed against the installation environment.
Share the component heat load, ambient temperature, solar exposure, duty cycle and allowable internal temperature. LYE can then review enclosure volume, spacing, ventilation or fan provisions, sun shields, heaters or drainage details; the final thermal design remains tied to the installed equipment and site conditions.
Yes. A dimensioned drawing is preferred, but a physical sample and clear reference photographs can also start the review. Material, thickness, openings, hardware, finish, labels, inspection points and packing are recorded before sampling or repeat production.
PDF and common 2D CAD drawings are suitable for most enclosure enquiries, while 3D files can help with complex assemblies. Include a revision number, units, tolerances and component references; file compatibility and any missing production information will be confirmed during review.
A sample or first article can be arranged for a new or customized product. The approval plan should identify dimensions, openings, fit, appearance, hardware, labels and packaging, together with the sample cost and timing agreed for the actual order.
Available documents may include approved drawings, packing lists, dimensional or appearance inspection records, product data and certificates applicable to the confirmed model. Destination-specific declarations or third-party testing must be requested before order placement so availability and scope can be verified.
Lead time is confirmed after the product scope, quantity, sample requirement and finish are known. Packing is reviewed against product weight, surface protection, destination and shipping method; if an issue is found after delivery, send the order reference, label, photographs and quantity affected so it can be traced and reviewed.
Related Products
Send Inquiry
FROM PRODUCT TO PROJECT
Review the installation context before quotation
Use the related solutions to check typical installation inputs, then send drawings, dimensions and quantities for a manufacturability review.
Relevant Solutions
All Solutions
ENGINEERED SOLUTION
Infrastructure Project Enclosure Solution
Customized electrical enclosures for municipal utilities, transport facilities, public engineering and outdoor service points, reviewed around site exposure, access and delivery documentation.
View Solution 
ENGINEERED SOLUTION
Renewable Energy Distribution Solution
PV grid-connection cabinets and outdoor distribution enclosures coordinated around protection, isolation, metering, cable interfaces and the actual installation environment.
View Solution 