LYX Series Information Box Modules
LYX series information box modules are manufactured by LYE Technology to add flexible telephone, data and CATV distribution inside any multimedia information box. The range includes telephone modules in 1-in-4-out and 1-in-7-out form, a 1-in-4-out data module, 1-in-4-out and 1-in-6-out CATV modules, and an integrated TV-telephone module.
- Telephone modules: LYX-A301 (1-in-4-out), LYX-A304 (1-in-7-out)
- Data module: LYX-B305, 1-in-4-out computer module, no switch function
- CATV modules: LYX-C301 (1-in-4-out), LYX-C302 (1-in-6-out)
- Integrated module: LYX-C303, 1-in-4-out telephone plus 1-in-4-out TV
- Mounting: Snaps into standard information box brackets
Information Box Modules: Key Features & Typical Use
Specify the Splits, Not the Cabinet
A property rarely needs the same distribution as its neighbour. The LYX module system lets the installer configure exactly the voice, data and video splits each household requires, so a studio flat and a large villa can use the same cabinet with different modules fitted rather than forcing both onto one fixed arrangement.Telephone Splitting in Two Depths
The telephone modules are offered as a 1-in-4-out unit and a 1-in-7-out unit, covering a typical apartment and a larger house respectively. Both mount into the same bracket, so upgrading from four to seven outlets is a module change rather than a reinstallation of the cabinet or additional cabling work.Data and CATV Distribution
A 1-in-4-out computer module provides data distribution without a switch function, which is the correct arrangement for a passive structured wiring hub, and CATV signal modules provide 1-in-4-out and 1-in-6-out television splitting. A combined module also provides 1-in-4-out telephone and 1-in-4-out television from one unit where space is tight.Tool-Light Installation
Modules snap into the standard brackets used across the LYX and LYX2 cabinets, so configuration is a matter of fitting modules rather than rewiring. That keeps installation time predictable, allows later changes to be made by a technician with basic hand tools, and means spares can be carried as individual modules rather than complete cabinets.Information Box Modules Specifications & Technical Data
| Parameter | Details |
|---|---|
| Series | LYX series information box modules |
| LYX-A301 | Telephone module, 1-in-4-out |
| LYX-A304 | Telephone module, 1-in-7-out |
| LYX-B305 | Data module, 1-in-4-out computer module, no switch function |
| LYX-C301 | CATV signal module, 1-in-4-out TV |
| LYX-C302 | CATV signal module, 1-in-6-out TV |
| LYX-C303 | TV-telephone integrated module, 1-in-4-out telephone and 1-in-4-out TV |
| Mounting | Snaps into standard information box brackets |
| Configuration | Modules mixed and matched per household |
| Function | Voice, data and CATV signal distribution |
| Compatible cabinets | LYX and LYX2 multimedia information box ranges |
| Application | Residential multimedia distribution |
LYX Modules — Flexible Voice, Data and TV Distribution
Multimedia information boxes are only useful if the distribution inside matches the property. The LYX module range provides that flexibility: telephone splitting in two depths, a data module, CATV signal modules in two sizes, and an integrated television-telephone unit for positions where space is limited.These components are also called structured wiring modules, weak current distribution modules or splitter modules, and they are compared with loose splitters and terminal blocks fitted inside the cabinet. A property rarely needs the same distribution as its neighbour, so the questions worth asking a manufacturer are which split ratios are held, whether the modules share one mounting bracket, and whether a module can be replaced on its own when a service changes.Telephone distribution is available as a 1-in-4-out and a 1-in-7-out module, covering a typical apartment and a larger house, and both mount into the same bracket, so increasing the number of outlets later is a module change rather than a new cabinet. CATV modules provide 1-in-4-out and 1-in-6-out television splitting for the same reason.The data module is a 1-in-4-out computer module without a switch function, which is the correct arrangement for a passive structured wiring hub, and the LYX-C303 combines 1-in-4-out telephone and 1-in-4-out television in one unit. All modules snap into the standard brackets used across the LYX and LYX2 cabinets.
Factory-Direct Information Box Modules Manufacturer & OEM / ODM
We Manufacture, You Brand
LYE Technology (Zhejiang) Co., Ltd. is a national high-tech enterprise and manufacturer in Wenzhou, China: sheet-metal fabrication, welding, powder coating, busbar machining and final assembly run on our own factory lines, and every unit is function-tested before it leaves the works. A LYX Series Information Box Modules that reaches your site carries the routine test behind it, not just the rating on the nameplate.We are one of the Top 10 Brands of China's small power distribution boxes and a drafter of national standards in this category, and we hold ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification. Because we are the manufacturer rather than a trading company, our sales engineers quote from your drawing in factory-direct terms, and OEM or ODM work is produced on the same lines as our standard products.For the LYX module range we assemble and test each module before dispatch, so a project supplied with several module types is not held up by one component that does not function.- OEM branding — custom colours, laser marking and your own project or retail packaging, applied at the factory.
- ODM options — ratings, configurations and internal layouts built around your drawings or single-line diagram.
- Certification — ISO9001, ISO14001, ISO45001, CCC, CE and TUV, with test documents supplied per project.
- MOQ — flexible quantities for a project or a trial order, with mixed types welcome in one shipment.

LYX telephone and CATV modules mounted in a standard bracket

Mixed module configuration in a multimedia information box
Information Box Modules Buying Guide from the Manufacturer
Ordering modules is a counting exercise: outlets required, by service type. These are the points we confirm.
- Count the telephone outlets required and choose between the 1-in-4-out and 1-in-7-out modules.
- Count the television outlets required and choose the 1-in-4-out or 1-in-6-out CATV module.
- Confirm whether a data module is needed and whether switch functionality is required.
- Confirm whether space is tight enough to justify the integrated television-telephone module.
- Send the outlet schedule per room and the cabinet model being used.
- Approve the module schedule, then production and dispatch.

Manufacturer & Sales Support for Wholesale Buyers

OEM / ODM
Learn more →Factory colours · Logo marking · Custom layout

Wholesale
Learn more →Factory pricing · Flexible MOQ · Global shipping

Distributor Support
Learn more →Account manager · Drawing support · Priority lead times
Configuring Multimedia Distribution Modules?
OEM/ODM, wholesale pricing and distributor support straight from the manufacturer — one enquiry gets you a factory-direct quotation for the LYX Series Information Box Modules, sized to your outlet schedule by room and the cabinet model the modules will be fitted into, with type-test documentation under the applicable national requirements for residential multimedia distribution equipment. Our sales team replies with a specification and an indicative price, so send your drawings and quantity.Contact Our Sales TeamInformation Box Modules — Frequently Asked Questions
What are information box modules?
They are modular components that provide telephone, data and CATV signal distribution inside a multimedia information box, snapping into standard brackets so the distribution can be configured per property. The LYX range includes 1-in-4-out and 1-in-7-out telephone modules, a 1-in-4-out data module, 1-in-4-out and 1-in-6-out CATV modules and an integrated television-telephone unit.What is a 1-in-4-out telephone module used for?
It takes a single incoming telephone line and distributes it to four outlets, which covers most apartments and small houses. Where more points are needed, the 1-in-7-out module provides the extra ways from the same bracket position, so increasing the number of telephone outlets later is a module change rather than new cabling work.What is the difference between a data module and a network switch?
A data module such as the LYX-B305 is a passive 1-in-4-out computer module without a switch function: it distributes a wired connection to the rooms and relies on the router upstream to handle switching and addressing. A network switch is active equipment that manages traffic. In a structured wiring hub the passive module is the correct choice, with switching handled by the router.Who manufactures multimedia distribution modules?
The category includes structured wiring brands and enclosure manufacturers who build their own module system around their own cabinets. Ask which split ratios are held, whether the modules mount in a standard bracket, and whether individual modules are supplied as spares so a service change does not require replacing the cabinet. LYE manufactures the LYX module range in Wenzhou, tests each module before dispatch, and holds ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification.How much do information box modules cost?
Indicative factory-direct pricing is roughly US$8 to US$120 per unit, depending on the module type, the split ratio and the quantity ordered. Because modules are supplied individually, spares can be held as components rather than complete cabinets, and a mixed module schedule for a project can be supplied in one shipment.
Download PDF
Electrical Cabinet Product Catalog
Mini Distribution Box Product Catalog
Distribution Box Product Manual
Fiber Optic Box Product Manual
Fan Module Manual
Use a distribution box for final circuits and compact branch protection; use a cabinet when the project needs larger incoming capacity, more feeder groups, metering, busbars or greater internal separation. The final choice should be checked against the single-line diagram, device list, available installation space and local project rules.
Provide the device schedule, circuit quantity, component dimensions, cable-entry direction, mounting method and required spare capacity. LYE also reviews door clearance, bending radius, heat-producing devices and the usable depth behind the mounting plate before confirming an enclosure size.
Start with the actual exposure to dust, rain, cleaning water and accidental contact rather than choosing the highest number by default. Cable entries, ventilation, door seals and installation workmanship affect the finished assembly, so the target rating and verification basis must be confirmed for the specific product and project.
Coated or galvanized steel is commonly considered for general indoor service, stainless steel for humid or corrosive locations, and engineering plastic for lightweight non-metallic applications. Material grade, thickness, UV exposure, chemical contact and earthing requirements must be confirmed against the installation environment.
Share the component heat load, ambient temperature, solar exposure, duty cycle and allowable internal temperature. LYE can then review enclosure volume, spacing, ventilation or fan provisions, sun shields, heaters or drainage details; the final thermal design remains tied to the installed equipment and site conditions.
Yes. A dimensioned drawing is preferred, but a physical sample and clear reference photographs can also start the review. Material, thickness, openings, hardware, finish, labels, inspection points and packing are recorded before sampling or repeat production.
PDF and common 2D CAD drawings are suitable for most enclosure enquiries, while 3D files can help with complex assemblies. Include a revision number, units, tolerances and component references; file compatibility and any missing production information will be confirmed during review.
A sample or first article can be arranged for a new or customized product. The approval plan should identify dimensions, openings, fit, appearance, hardware, labels and packaging, together with the sample cost and timing agreed for the actual order.
Available documents may include approved drawings, packing lists, dimensional or appearance inspection records, product data and certificates applicable to the confirmed model. Destination-specific declarations or third-party testing must be requested before order placement so availability and scope can be verified.
Lead time is confirmed after the product scope, quantity, sample requirement and finish are known. Packing is reviewed against product weight, surface protection, destination and shipping method; if an issue is found after delivery, send the order reference, label, photographs and quantity affected so it can be traced and reviewed.
Related Products
Send Inquiry
FROM PRODUCT TO PROJECT
Review the installation context before quotation
Use the related solutions to check typical installation inputs, then send drawings, dimensions and quantities for a manufacturability review.
Relevant Solutions
All Solutions
ENGINEERED SOLUTION
Infrastructure Project Enclosure Solution
Customized electrical enclosures for municipal utilities, transport facilities, public engineering and outdoor service points, reviewed around site exposure, access and delivery documentation.
View Solution 
ENGINEERED SOLUTION
Renewable Energy Distribution Solution
PV grid-connection cabinets and outdoor distribution enclosures coordinated around protection, isolation, metering, cable interfaces and the actual installation environment.
View Solution 