HomeProductsLow Voltage CabinetGCK Low-Voltage Switch Cabinet

GCK Low-Voltage Switch Cabinet

The GCK low-voltage switch cabinet is manufactured by LYE Technology on a 25 mm module C-section frame with an 1800 mm effective height. Eight drawer sizes from 8E/4 to 24E allow up to 36 outgoing circuits in one cubicle, which is the highest circuit density in our low-voltage cabinet range.

  • Rated working voltage: 400 V (690 V) and below
  • Rated current: Up to 6300 A
  • Frame modulus: E = 25 mm C-section, effective height 1800 mm
  • Drawer sizes: 8E/4, 6E/2, 8E/2, 6E, 8E, 12E, 16E, 24E
  • Circuits per drawer: 8E/4 up to 36, 6E/2 up to 24, 8E/2 up to 18, 8E up to 9
Send Inquiry

GCK Low-Voltage Switch Cabinet: Key Features & Typical Use

The Highest Circuit Density of the Three Series

Eight drawer specifications — 8E/4, 6E/2, 8E/2, 6E, 8E, 12E, 16E and 24E — let one cubicle hold as many as 36 outgoing circuits in 8E/4 drawers. For a plant with a long list of small motor and distribution circuits, that means fewer cubicles, a shorter busbar run and a smaller switchroom footprint for the same number of ways.

Interlocked Positions on Every Drawer

All eight drawer sizes provide connected, test and disconnected positions with reliable mechanical interlocking. The result is a repeatable isolation routine: an operator can move a feeder to the test position and verify it without exposing the busbar, regardless of whether the drawer holds a 32 A breaker or a 630 A one.

Propulsion Matched to Breaker Size

The smaller 8E/4, 6E/2 and 8E/2 drawers use hand-pull propulsion with FZID metal split adapter units; 6E and 8E drawers also use a pull mechanism, while the larger 12E, 16E and 24E drawers switch to a hand-cranked mechanism. Matching the mechanism to the unit keeps insertion force low and makes accidental partial engagement much less likely.

Modular Frame, Repeatable Build

The frame is assembled from 25 mm module C-section steel with an 1800 mm effective height. Because the module grid is carried through the busbar compartment, the cable compartment and the door furniture, a GCK cubicle built for one project can be extended later with a cubicle built for another — the same reason utilities and industrial groups use this platform across several sites.

GCK Low-Voltage Switch Cabinet Specifications & Technical Data

ParameterDetails
ProductGCK low-voltage switch cabinet
Main frameC-section steel, modulus E = 25 mm, effective height 1800 mm
Drawer specifications8E/4, 6E/2, 8E/2, 6E, 8E, 12E, 16E, 24E
Circuits per drawer size8E/4 up to 36; 6E/2 up to 24; 8E/2 up to 18; 8E up to 9
Drawer positionsConnected, test, disconnected with mechanical interlock
Adapter unitFZID metal split adapter unit for 8E/4, 6E/2 and 8E/2
Propulsion mechanismHand-pull for 8E/4, 6E/2, 8E/2, 6E, 8E; hand-cranked for 12E, 16E, 24E
Rated frequency50–60 Hz, three-phase AC
Rated working voltage400 V (690 V) and below
Rated current6300 A and below
Typical dutiesPower distribution, motor centralised control, capacitor compensation
Typical installationsPower plants, petroleum and chemical plants, hospitals, railways, airports, mining, buildings

GCK — Maximum Outgoing Circuits per Cubicle

Once a switchroom has been designed, the expensive part is the space between the cubicles, not the breakers inside them. The GCK is built to reduce that space: on a 25 mm module frame with an 1800 mm effective height, a single cubicle can carry 36 outgoing circuits in 8E/4 drawers, or a mix of small and large ways without wasted modules.This type is also written as GCK drawer-type low-voltage switchgear or a GCK modular LV switchboard, and it is frequently compared with MNS and GCS boards on the same shortlist. The deciding factor is usually circuit density: where a plant has a long list of small motor and distribution ways, fewer cubicles means a shorter busbar run, a smaller switchroom and less cable — which is worth more than the unit price difference between platforms.Every drawer size offers connected, test and disconnected positions with mechanical interlocking, and the propulsion mechanism changes with the unit: a light pull action for the small drawers with FZID split adapters, a cranked mechanism for the 12E, 16E and 24E units. Service staff get one isolation routine across the whole board.The platform is rated for three-phase 50–60 Hz systems at 400 V (690 V) and below with currents up to 6300 A, and is used for power distribution, centralised motor control and compensation in power plants, chemical and petroleum works, hospitals, railways, airports and mining operations. LYE supplies the GCK factory-direct and builds busbar and compartment layouts around your drawings.
GCK Low-Voltage Switch Cabinet

Factory-Direct GCK Low-Voltage Switch Cabinet Manufacturer & OEM / ODM

We Manufacture, You Brand

LYE Technology (Zhejiang) Co., Ltd. is a national high-tech enterprise and manufacturer in Wenzhou, China: sheet-metal fabrication, welding, powder coating, busbar machining and final assembly run on our own factory lines, and every unit is function-tested before it leaves the works. A GCK Low-Voltage Switch Cabinet that reaches your site carries the routine test behind it, not just the rating on the nameplate.We are one of the Top 10 Brands of China's small power distribution boxes and a drafter of national standards in this category, and we hold ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification. Because we are the manufacturer rather than a trading company, our sales engineers quote from your drawing in factory-direct terms, and OEM or ODM work is produced on the same lines as our standard products.For the GCK we punch the 25 mm module frame and fit the drawer mechanisms in our own works, so a high-density drawer schedule is a production detail rather than a design change.
  • OEM branding — custom colours, laser marking and your own project or retail packaging, applied at the factory.
  • ODM options — ratings, configurations and internal layouts built around your drawings or single-line diagram.
  • Certification — ISO9001, ISO14001, ISO45001, CCC, CE and TUV, with test documents supplied per project.
  • MOQ — flexible quantities for a project or a trial order, with mixed types welcome in one shipment.

GCK Low-Voltage Switch Cabinet Buying Guide from the Manufacturer

A GCK board is ordered by drawer schedule rather than by part number, so the checklist below is what we confirm before we release a drawing.
  1. Confirm the system: three-phase 50–60 Hz, 400 V (690 V) and below, up to 6300 A.
  2. Count the outgoing circuits and group them by breaker frame to fix the drawer sizes.
  3. Decide how many cubicles the board needs and allow spare ways for later expansion.
  4. Confirm the compartment arrangement for incoming, bus-tie, motor control and compensation sections.
  5. Send the single-line diagram, drawer schedule and site conditions.
  6. Approve drawings, then assembly, routine testing of every drawer and dispatch with test records.
Sheet-metal laser cutting area

Manufacturer & Sales Support for Wholesale Buyers

Routine testing bay for distribution equipment
Custom finishes, laser marking and packaging produced on the factory line behind the standard GCK, with layouts set from your drawings.
Factory colours · Logo marking · Custom layout
Cabinet final assembly line at the LYE works
Factory-direct pricing from the manufacturer with flexible MOQ on the GCK and the wider low voltage cabinet range your distributors already stock.
Factory pricing · Flexible MOQ · Global shipping
Sheet-metal laser cutting area at the LYE works

Distributor Support

Learn more →
Dedicated account management and factory sales support, drawing assistance and priority production for partners adding low voltage cabinet to their range.
Account manager · Drawing support · Priority lead times

Specifying a GCK Distribution Board?

OEM/ODM, wholesale pricing and distributor support straight from the manufacturer — one enquiry gets you a factory-direct quotation for the GCK Low-Voltage Switch Cabinet, sized to your outgoing circuit list, drawer schedule and the spare capacity you want to leave in the board, with type-test documentation under IEC 60439-1 and IEC 60947. Our sales team replies with a specification and an indicative price, so send your drawings and quantity.Contact Our Sales Team

GCK Low-Voltage Switch Cabinet — Frequently Asked Questions

What is a GCK low-voltage switch cabinet?

It is a low-voltage distribution cabinet assembled on a 25 mm module C-section frame with an 1800 mm effective height, used for power distribution, centralised motor control and capacitor compensation in three-phase 50–60 Hz systems at 400 V (690 V) and below, with rated currents up to 6300 A. It offers eight drawer sizes from 8E/4 to 24E.

How many outgoing circuits can a GCK cabinet carry?

Up to 36 circuits in 8E/4 drawers, up to 24 in 6E/2, up to 18 in 8E/2 or up to nine in 8E drawers. Every drawer size provides connected, test and disconnected positions with mechanical interlocking, so the isolation routine is the same whether the drawer holds a small outgoing way or a large feeder, which simplifies operator training and switching procedures.

What types of drawer-type switchgear are available?

Modular withdrawable boards are usually grouped by module step and by the drawer sizes offered. A 25 mm step with eight drawer sizes suits a mixed load list and the highest circuit counts, while a 20 mm step with fewer sizes suits medium-sized circuits. Within a board, small drawers use hand-pull propulsion with split adapter units and larger drawers use a hand-cranked mechanism.

Who are the main manufacturers of drawer-type switchgear?

The platform names in this category are built by many factories, so the same name can describe quite different equipment. Relevant questions are whether the frame is punched on the supplier's own line, which drawer sizes they actually manufacture rather than buy in, and whether routine test records and type-test documents are issued per project. LYE manufactures the GCK frame, drawers and shell in Wenzhou and holds ISO9001, ISO14001, ISO45001, CCC, CE and TUV certification.

How much does a GCK switchboard cost?

Indicative factory-direct pricing is roughly US$1,500 to US$6,000 per cubicle, depending on the drawer schedule, busbar rating, cubicle count and quantity. Because drawer-type boards are configured to the outgoing circuit list, the comparison between suppliers is only meaningful once the drawer sizes, the propulsion mechanisms and the heat load per cubicle have been fixed, so send the schedule for a specific figure.